ASTM E1155 - FF and FL tests - Contractor Talk
Nov 28, 2007 · ASTM E1155 - FF and FL tests Jump to Latest 19K views 9 replies 6 participants last post by Floordude Jan 30, 2008
Professional Construction and Remodeling Forum - Contractor Talk
May 3, 2007 · I actualy AM looking for floor flatness (FF) and floor levelness (FL). I cant afford the time or money to truly observe ASTM E1155. I'm dealing with an 8000sq ft floating floor so if it is not level it will creep if it is not flat I have to grind it down.
Mortar Cement - ASTM C 1329 - ASTM C 1329 | Contractor Talk
Apr 16, 2014 · ASTM C 1329 and IBC 2103.7 standards for Mortar Cement is the guide lines manufacturer must meet when making Type N, S and M masonry mortars. Look on the plan if you have to meet ASTM C 270 also, which is cement mix proportion requirements, like the mix should contain 2-1/4 to 3 parts loose damp masonry sand...
differences in roofing felt | Contractor Talk - Professional ...
Jul 28, 2010 · We use ASTM #30 for the eve and valleys and ASTM #15 for the field. The ASTM #30 we use is 44" tall and almost impossible to work with in the winter due to its strength. The non rated #30 is 36" tall (which only gives you about 6" coverage above the inside wall on a 2 foot overhang) and it feels lighter than ASTM #15.
Manufacturer Identification | Contractor Talk - Professional ...
Mar 28, 2014 · Anyone happen to know the manufacturer for this piping? It is likely from the early 90's. It has 1/2"-TYPE M-HMP-W-MADE IN THE USA-ASTM-B8 printed on the exterior and also 1/2"-TYPE M-HMP-W-MADE IN THE USA stamped on the exterior. Any possible ideas would be appreciated. The pictures are from two different runs of pipe in two different homes ...
Adjuster said it was too cold for brittle test? - Contractor Talk
Mar 11, 2019 · Had to deal with an allstate adjuster today for wind damage on a roof. Roof probably 15 years old. Only approved repairs, even though shingles failed the brittle test and cracked. They should have bought the whole roof. Instead, he said it doesnt matter because the brittle test only counts if...
Apr 17, 2012 · Tensile Strength (ASTM D412) 50 psi (typical) Peel Strength (7 Days Water Immersion) Color Black 4.2 lbs./in. (typical) Water Resistance No re-emulsification or loss of adhesion Drying Time @ 50% R.H. 68ºF Resistance to Hydrostatic Head (20ºC) 8 …
Paintable non-combustible material for fireplace surround?
Feb 12, 2020 · Technically, our installation does not meet ASTM -E 136, but we got approval from the building department that the drywall was encapsulated in a non-combustible material. BTW, I don't believe a painted anything will work. Paint is actually combustible. Non-Combustible Materials Specification Material which will not ignite and burn. Such ...
• ASTM International (ASTM) • International Code Council (ICC) • National Fire Protection Association (NFPA) For questions about vinyl siding, please contact: Matt Dobson, Director of Code and Regulatory Vinyl Siding Institute, Inc. National Housing Center 1201 15th St, NW, Suite 220 Washington, DC 20005 [email protected]
Apr 11, 2011 · layer of minimum 72-pound mineral-surfaced non-perforated cap sheet complying with ASTM D 3909, at least 36-inch-eide running with full length of the valley. R327.5.4 Roof gutters: Roof gutters shall be provided with the means to prevent the accumulation of leaves and debris in the gutter. Vents – Section R327.6